You are here
Error message
- Notice: Trying to get property of non-object in _tecnoclima_application_header_elenco_prodotti_CONTENT() (line 537 of /var/www/vhosts/tecnoclimaspa.com/httpdocs/sites/all/modules/tecnoclima_application/tecnoclima_application.module).
- Notice: Trying to get property of non-object in eval() (line 4 of /var/www/vhosts/tecnoclimaspa.com/httpdocs/sites/all/modules/views/plugins/views_plugin_argument_default_php.inc(66) : eval()'d code).
- Notice: Trying to get property of non-object in eval() (line 2 of /var/www/vhosts/tecnoclimaspa.com/httpdocs/sites/all/modules/views/plugins/views_plugin_argument_default_php.inc(66) : eval()'d code).
- Notice: Trying to get property of non-object in eval() (line 3 of /var/www/vhosts/tecnoclimaspa.com/httpdocs/sites/all/modules/views/plugins/views_plugin_argument_default_php.inc(66) : eval()'d code).
CF-XTRIM Condensing premix gas roof-top
ROOF-TOP CF-Xtrim Tecnoclima are packaged autonomous air treatment unit designed for heating with gas or heat pump, cooling, air filtration, and air renewal with recuperation module.



to 206

to 171

to 26.000

Peculiarity:
- High energy efficiency
- Flexible installation
- Versatile and easy to use
- Double energy source for heating cf-xTRIM/p
- Gas heat exchanger efficiency up to 106%
- Air renewal
- Heat recovery
- R410A refrigerant
Description
The units CF-XTRIM Tecnoclima are designed and equipped to simplify, as well as reduce the installation process to a minimum, with high energy efficiency in air conditioning in environments, supported by the intelligent and advanced independent management of thermal or cooling energy depending on the needs of the environment being treated: heating or cooling, only when needed.
The units CF-XTRIM Tecnoclima are available in several versions and configurations to respond to a broad range of user needs. Suitable for environments with medium and large volumes, such as shops, showrooms, gyms, supermarkets, shopping centres, cinemas, theatres etc. Designed for high-efficiency heat recovery in applications where air renewal is necessary, guaranteeing excellent air quality and compliance with Laws and Standards of reference.
CF-XTRIM GAS HEATING AND THERMODYNAMIC COOLING VERSION
The CF-XTRIM version proposes gas fired heating with direct exchange and cooling through a thermodynamic cycle with R410A compression. The heating/cooling operating mode is automatically managed (depending on needs) from the unit’s micro-processor control (X-CONTROL) if set up in automatic mode, or alternatively manually through a direct selection from the remote panel by the user.
CF-XTRIM/P GAS HEATING AND REVERSE HEAT PUMP VERSION
The CF-XTRIM/P version proposes a double heating source: gas combustion and thermodynamic cycle with R410A compression (heat pump). Gas combustion heating, or rather with the heat pump, is automatically managed from the unit’s micro-processor control (X-CONTROL) depending on thermal load needs, the external air temperature and the optimisation of energy consumption, thereby adapting parameters to the specific application. The heat pump heating mode can be selected (from the remote control panel) with an external air temperature up to -5°C.
M-CFX SUPPLEMENTARY MIXING BOX - AIR RENEWAL AND FREE-COOLING
The M-CFX module, integrated into the CF-XTRIM unit, offers the following additional functions:
- Air renewal in environments where regulation is based on air quality control (accessory sensor) or where specific conditions need to be met;
- Free-cooling with the total/partial emission of fresh air into environments where the external temperature conditions are favourable.
The M-CFX module includes a fan unit to recover air from the environments being treated, and three motorised dampers to manage the intake of fresh air, and the recirculation and expulsion of exhaust air. The three dampers are automatically opened/closed by the CF-XTRIM (/P) rooftop unit electronics.
M-RCFX SUPPLEMENTARY MODULE FOR AIR RECOVERY, RENEWAL AND FREE-COOLING
The M-RCFX module, integrated into the CF-XTRIM unit, offers the following additional functions:
- Air renewal in environments where regulation is based on air quality control (accessory sensor) or where specific conditions need to be met;
- Energy recovery from exhaust air through a direct heat exchange, in a dedicated exchanger, between the air being expelled and the fresh air;
- Free-cooling with the total/partial emission of fresh air into environments where the external temperature conditions are favourable.
The M-RCFX module includes heat exchanger (cross-flow plate type) between the exhaust air and fresh air, a fan unit to recover air from the environments being treated, and a set of motorised dampers to manage the intake of fresh air and the recirculation and expulsion of exhaust air. The dampers are automatically opened/closed directly by the CF-XTRIM (/P) rooftop unit electronics.
Dimensions
Model | Overall dimensions mm | ||
---|---|---|---|
A | B | C | |
100 | 1.850 | 1.450 | 1.180 |
200 | 2.750 | 1.700 | 1.380 |
300 | 2.750 | 1.700 | 1.380 |
400 | 3.250 | 2.250 | 1.380 |
500 | 3.250 | 2.250 | 1.380 |
550 | 3.250 | 2.250 | 1.480 |
600 | 3.250 | 2.250 | 2.270 |
700 | 3.250 | 2.250 | 2.270 |
Model | Overall dimensions mm | ||
---|---|---|---|
A | B | C | |
100 | 1.400 | 590 | 1.080 |
200 | 1.700 | 750 | 1.300 |
300 | 1.700 | 750 | 1.300 |
400 | 2.100 | 1.100 | 1.300 |
500 | 2.100 | 1.100 | 1.300 |
550 | 2.150 | 1.100 | 1.400 |
600 | 2.550 | 2.250 | 1.445 |
700 | 2.550 | 2.250 | 1.445 |
Model | Overall dimensions mm | ||
---|---|---|---|
A | B | C | |
100 | 1.850 | 1.200 | 1.100 |
200 | 2.500 | 1.700 | 1.300 |
300 | 2.500 | 1.700 | 1.300 |
400 | 2.900 | 2.050 | 1.480 |
500 | 2.900 | 2.050 | 1.480 |
550 | 3.550 | 2.250 | 1.480 |
600 | 3.550 | 2.250 | 1.450 |
700 | 3.550 | 2.250 | 1.450 |
Technical features
CF-XTRIM
Model | Unit | 100 | 200 | 300 | 400 | 500 | 550 | 600 | 700 |
---|---|---|---|---|---|---|---|---|---|
Nominal air flow rate | m3/h | 3.500 | 6.000 | 7.500 | 9.700 | 12.800 | 17.000 | 21.000 | 26.000 |
Useful static pressure | Pa | 250 |
GAS HEATING - HEATING CAPACITY MODULATION
Model | Unit | 100 | 200 | 300 | 400 | 500 | 550 | 600 | 700 | |
---|---|---|---|---|---|---|---|---|---|---|
Heating capacity input | Max | kW | 29,1 | 58,2 | 67,6 | 99,6 | 118 | 118 | 165,8 | 206,8 |
Min | kW | 9,4 | 9,4 | 13,3 | 18,4 | 20 | 20 | 40,6 | 40,6 | |
Heating capacity output | Max | kW | 28 | 56 | 65 | 96 | 114 | 114 | 163 | 204 |
Min | kW | 10 | 10 | 14 | 19 | 21 | 21 | 43 | 43 | |
Max/Min efficiency | Max | % | 96,1 | 96,1 | 96,1 | 96,4 | 96,6 | 96,5 | 97,5 | 99,1 |
Min | % | 106,5 | 106,5 | 105,1 | 103,2 | 105,1 | 104,2 | 105,2 | 106 |
THERMODYNAMIC COOLING
Model | Unit | 100 | 200 | 300 | 400 | 500 | 550 | 600 | 700 |
---|---|---|---|---|---|---|---|---|---|
Total cooling capacity | kW | 23,8 | 35,6 | 48 | 64,6 | 92,5 | 113,2 | 139,8 | 170,7 |
Sensitive cooling capacity | kW | 17,2 | 25,9 | 35,6 | 47 | 65 | 82,5 | 101 | 122 |
Compressor power absorption | kW | 6 | 9,1 | 12,7 | 16,3 | 22,7 | 29,8 | 35,2 | 49,8 |
EER compressors | - | 3,97 | 3,91 | 3,78 | 3,96 | 4,07 | 3,8 | 3,97 | 3,43 |
No. compressors | - | 1 | 2 | 2 | 2 | 2 | 2 | 4 | 4 |
No. circuits | - | 1 | 1 | 1 | 1 | 1 | 1 | 2 | 2 |
Power stages | - | 1 | 2 | 2 | 3 | 3 | 3 | 4 | 4 |
SOUND LEVEL
Model | Unit | 100 | 200 | 300 | 400 | 500 | 550 | 600 | 700 |
---|---|---|---|---|---|---|---|---|---|
Sound power | dB(A) | 77 | 77 | 79 | 79 | 81 | 83 | 82 | 85 |
Cooling operating conditions: external T 35 °C / R.H. 50% - internal T 27 °C / R.H. 47%.
CF-XTRIM/P
Model | Unit | 100 | 200 | 300 | 400 | 500 | 550 | 600 | 700 |
---|---|---|---|---|---|---|---|---|---|
Nominal air flow rate | m3/h | 3.500 | 6.000 | 7.500 | 9.700 | 12.800 | 17.000 | 21.000 | 26.000 |
Useful static pressure | Pa | 250 |
GAS HEATING - HEATING CAPACITY MODULATION
Model | Unit | 100 | 200 | 300 | 400 | 500 | 550 | 600 | 700 | |
---|---|---|---|---|---|---|---|---|---|---|
Heating capacity input | Max | kW | 29,1 | 58,2 | 67,6 | 99,6 | 118 | 118 | 165,8 | 206,8 |
Min | kW | 9,4 | 9,4 | 13,3 | 18,4 | 20 | 20 | 40,6 | 40,6 | |
Heating capacity output | Max | kW | 28 | 56 | 65 | 96 | 114 | 114 | 163 | 204 |
Min | kW | 10 | 10 | 14 | 19 | 21 | 21 | 43 | 43 | |
Efficiency | Max | % | 96,1 | 96,1 | 96,1 | 96,4 | 96,6 | 96,5 | 97,5 | 99,1 |
Min | % | 106,5 | 106,5 | 105,1 | 103,2 | 105,1 | 104,2 | 105,2 | 106 |
THERMODYNAMIC HEATING - HEAT PUMP (1)
Model | Unit | 100 | 200 | 300 | 400 | 500 | 550 | 600 | 700 |
---|---|---|---|---|---|---|---|---|---|
Heating capacity | kW | 21,5 | 32,1 | 45,9 | 62,2 | 85,2 | 106,4 | 133,3 | 167,2 |
Compressor power absorption | kW | 4,79 | 6,9 | 10,34 | 13,9 | 19,34 | 23,75 | 28,88 | 38,84 |
COP compressors | - | 4,48 | 4,65 | 4,44 | 4,46 | 4,40 | 4,48 | 4,61 | 4,30 |
No. compressors | - | 1 | 2 | 2 | 2 | 2 | 2 | 4 | 4 |
No. circuits | - | 1 | 1 | 1 | 1 | 1 | 1 | 2 | 2 |
Power stages | - | 1 | 2 | 2 | 3 | 3 | 3 | 4 | 4 |
THERMODYNAMIC COOLING (1)
Model | Unit | 100 | 200 | 300 | 400 | 500 | 550 | 600 | 700 |
---|---|---|---|---|---|---|---|---|---|
Total cooling capacity | kW | 21,4 | 32,4 | 45,7 | 62,6 | 87,6 | 106,9 | 132,2 | 164,2 |
Sensitive cooling capacity | kW | 16,3 | 24,4 | 34,8 | 46,1 | 64,1 | 80,5 | 100 | 117,3 |
Compressor power absorption | kW | 5,93 | 8,86 | 12,96 | 16,1 | 22,55 | 29,1 | 35,38 | 49,2 |
EER compressors | - | 3,6 | 3,66 | 3,53 | 3,88 | 3,88 | 3,68 | 3,74 | 3,34 |
No. compressors | - | 1 | 2 | 2 | 2 | 2 | 2 | 4 | 4 |
No. circuits | - | 1 | 1 | 1 | 1 | 1 | 1 | 2 | 2 |
Power stages | - | 1 | 2 | 2 | 3 | 3 | 3 | 4 | 4 |
Sound power | dB(A) | 77 | 77 | 79 | 79 | 81 | 83 | 82 | 85 |
Operating conditions (1): Heating: external T 7 °C / U.R. 87% - internal T 20 °C / U.R. 50% • Cooling: external T 35 °C / U.R. 50% - internal T 27 °C / U.R. 47%.
MIXING BOX M-CFX
Model | Unit | 100 | 200 | 300 | 400 | 500 | 550 | 600 | 700 |
---|---|---|---|---|---|---|---|---|---|
Nominal air flow rate | m3/h | 3.500 | 6.000 | 7.500 | 9.700 | 12.800 | 17.000 | 21.000 | 26.000 |
Useful static pressure | Pa | 250 |
ELECTRICAL DATA
Model | Unit | 100 | 200 | 300 | 400 | 500 | 550 | 600 | 700 |
---|---|---|---|---|---|---|---|---|---|
Supply | - | 400 V – 3 Ph – 50 Hz | |||||||
Max electrical power | kW | 0,75 | 1,1 | 1,5 | 2,2 | 3,0 | 5,5 | 5,5 | 5,5 |
M-RCFX RECOVERY MODULE
Model | Unit | 100 | 200 | 300 | 400 | 500 | 550 | 600 | 700 |
---|---|---|---|---|---|---|---|---|---|
Nominal air flow rate Fresh / exhaust |
m3/h | 3.500 | 6.000 | 7.500 | 9.700 | 12.800 | 17.000 | 21.000 | 24.000 |
Useful static pressure air recovery fan |
Pa | 200 |
HEATING PERFORMANCE
Model | Unit | 100 | 200 | 300 | 400 | 500 | 550 | 600 | 700 |
---|---|---|---|---|---|---|---|---|---|
Recovered thermal power | kW | 16,3 | 27,2 | 33,1 | 42,7 | 54,4 | 76,1 | 94,0 | 106,0 |
Recuperator efficiency | % | 55,8 | 54,2 | 52,8 | 52,6 | 50,8 | 53,5 | 53,5 | 52,6 |
Reference conditions | % | External air T. -5°C , R.H. 90% - Exhaust air T. 20 °C , R.H. 50 % |
COOLING PERFORMANCE
Model | Unit | 100 | 200 | 300 | 400 | 500 | 550 | 600 | 700 |
---|---|---|---|---|---|---|---|---|---|
Recovered thermal power | kW | 4,7 | 8,2 | 10,1 | 13 | 16,6 | 22,2 | 27,5 | 30,8 |
Recuperator Efficiency | % | 50,4 | 51,2 | 50,0 | 50,0 | 48,2 | 48,8 | 48,8 | 48,0 |
Reference Conditions | % | External air T. 35°C , R.H. 50% - Exhaust air T. 27 °C , R.H. 47 % |
ELECTRICAL DATA
Model | Unit | 100 | 200 | 300 | 400 | 500 | 550 | 600 | 700 |
---|---|---|---|---|---|---|---|---|---|
Supply | - | 400 V – 3 Ph – 50 Hz | |||||||
Max electrical power | kW | 1,1 | 1,5 | 2,2 | 2,2 | 4,0 | 5,5 | 7,5 | 11,0 |
Control
X-CONTROL
The new generation of control electronics has been designed to ensure the unit’s maximum energy efficiency, even with supplementary modules, in various operating conditions, and at the same time guarantee maximum system reliability. With X-CONTROL it is possible to manage all unit functions, to control and regulate operating parameters relative to both the air treatment section and the thermodynamic section (cooling circuit).
![]() |
X-CONTROL includes:
Main functions of X-CONTROL:
|
![]() |
|
![]() |
Original accessories
- PR-TOUCH remote control panel with interactive screen (touch screen).
- Interface cards for protocols other than MODBUS.
- S-CFX mixing kit including motorised dampers for air recirculation and renewal.
- Sealed air temperature remote probe.
- Air quality sensor (CO2 e VOC).
- Smoke detector and reactive device on dampers.
- Humidity sensors in versions for external and duct installations.
- High and low pressure gauge for cooling circuits.
- Axial fan speed regulator CVA with pressure switch to vary the rotation speed in relation to the condensation/evaporation pressure.
- SMART-SW software for remote monitoring and management via PC.
- Air filters with efficiency class F5 and F7.
- Dampers for recirculated air and fresh air (installation in duct for CF-XTRIM 600/700) in manual or motorised versions.
- Rain protection cap for external air inlet.
- Anti-vibration supports for interface with supporting/resting base.








